-11%
, ,

Mecer Smart UPS 6KVA


Mecer 6000VA (4800W) 6KVA Smart Tower UPS ; PHASE, Single phase with ground ; INPUT ; Input Voltage Range, 110-300 VAC (Based on load at 50%); 176-300 VAC

KSh200,000.00 KSh225,000.00

Compare

Mecer 6000VA (4800W) 6KVA Smart Tower UPS

Mecer 6000VA (4800W) 6KVA Smart Tower UPS Features include;
• True double-conversion online UPS
• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.99
• Output power factor 0.8
• Converter mode available
• ECO mode operation for energy saving (only available for 1-3KVA)
• Generator compatible
• Adjustable battery numbers only available for 6K and up models
• Smart SNMP works well with either USB or RS-232 together
• Emergency power-off function only available for 6K and up models

Mecer 6000VA (4800W) 6KVA Specifications and features

Product Code ME-6000-WPTUspacer
CAPACITY 6000 VA / 4800 W
PHASE Single phase with ground
INPUT
Input Voltage Range 110-300 VAC (Based on load at 50%); 176-300 VAC (Based on load at 100%)
Nominal Voltage 208/220/230/240 VAC
Frequency Range 46~54 Hz or 56~64 Hz
Power Factor >= 0.99 @ Nominal Voltage (100% load)
OUTPUT
Voltage Regulation ± 1%
Output Voltage 208/220/230/240 VAC
Frequency Range (Batt. Mode) 50 Hz or 60 Hz ± 0.1 Hz
Transfer Time : AC Mode to Battery Mode Zero
Transfer Time : Inverter to Bypass Zero
Transfer Time : Waveform (Batt. Mode) Pure Sine Wave
Current Crest Ratio 3::1
Harmonic Distortion  3% THD (Linear Load);  5% THD (Non-linear Load)
Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz
EFFICIENCY
Battery Mode 0.9
AC Mode 0.92
BATTERY
Long-run Model : Battery Type Depending on the capacity of external batteries
Long-run Model : Charging Current (max.) 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Long-run Model : Charging Voltage 273 VDC ± 1% (Based on 20pcs bateries)
Long-run Model : Numbers 16~20 (Adjustable)
Standard Model : Battery Type 12 V / 9 Ah
Standard Model : Charging Current (max.) 1A/2A
Standard Model : Charging Voltage 218.4 VDC ± 1%, 273 VDC ± 1%
Standard Model : Numbers 16, 20
Standard Model : Typical Recharge Time 9 hours recover to 90% capacity
INDICATORS
LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
ENVIRONMENT
Operating Humidity 0~95% RH @ 0- 50°C (non-condensing)
Noise Level Less than 55dB @ 1 Meter
PHYSICAL
Standard Model : Dimension, D x W x H (mm) 369 x 190 x 688, 442 x 190 x 688
Standard Model : Net Weight (kgs) 61, 74
Long-run Model : Dimension, D x W x H (mm) 369 x 190 x 318
Long-run Model : Net Weight (kgs) 12
MANAGEMENT
Optional SNMP Power management from SNMP manager and web browser
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, and MAC

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Mecer Smart UPS 6KVA”

There are no reviews yet.